The jockey touch jockey pump controllers operate acrosstheline, where full voltage is applied to the motor for starting by the use of a single motor starter. Circuit breakers xtjp xtjy jockey pump controllers incorporate eaton combination motor controllers, which combine the circuit breaker and overload in one device. This page provides information about the individual parts common across all sizes of ac 8100 horizontal split case fire pumps. Most stationary fire pump assemblies are installed with devices that automatically sense a pressure loss in a fire protection. Shop the jockey online catalog for new arrivals and great deals. Ac fire pump offers a range of vertical inline pumps.
Pressure maintenance jockey pumps fire protection equipment. Firetrol fta556e xg jockey pump controllers are intended for use with fire pump systems. Use the download button below or simple online reader. Standard for the installation of stationary pumps for fire. Details and requirements pdf notes fire pump room design, details and requirements pdf notes 7122018 02. Pump detailed centrifugal pump centrifugal centrifugal collectors centrifugal pumps centrifugal coprssor fire pump jockey pump procuring centrifugal pumps caltlogue of centrifugal pumps centrifugal blower design york centrifugal chiller manual pdf carrier centrifugal chiller manual cameron the turbo air 6000. Jockey pump controllers are available for across theline starting. The jockey pump, an important part of a fire protection system. That small guy on the horse is referred to as a jockey. Multistage diesel fire pump diesel electric jockey fire pump set more2 electric fire pump xbdl electric fire pumps xbdw horizontal electric fire pumps xbddl multistage fire pump xbdgdl centrifugal multistage fire pump more2 fire pump system home used fire pump unit diesel electric jockey fire pump packages more2 others sewage pumping station. Most stationary fire pump assemblies are installed with devices that automatically sense a pressure loss in a fire protection system, and start running to supply water or boost pressure in that system. Ac series 8100 parts guide pdf for purchasing parts please see our ac series 8100 repair kits we offer 3 levels of repair kits for each pump. Since the jockey pump is not required to be listed, the control valves and check valve are not required to be listed. Xtjl jockey lite pump controllers models or technical.
Download a pdf of our users guide and sample report for more information about the software. The 1580 series fire pumps are designed to provide water to stand pipe, sprinkler, chemical mitigation and hydrant systems for fire suppression in industrial and commercial facilities. Color touchscreen display all controller models are equipped with a microprocessor based, color touchscreen which allows the user to monitor and program all functions and values. By navigating our website, you accept our use of cookies. A microprocessor based jockey pump controller for controlling operation of a jockey pump used to maintain pressure within a fire pump system. There is a small guy riding on top of or above a large horse. Ul listed jockey pump controller model nfyjsd1 reduced voltage star delta open transition model nfyjdo1 direct on line stardelta starting timer. The pump is used in conjun ction with suitable sig. Us201008054a1 microprocessor based jockey pump controller. The fire protection solutions for mainland applications include entire pump systems, complete with jockey pumps and main pumps that are either diesel or electrical driven, while a dedicated range of grundfos offshore pumps is available for vessels and oil rigs. Brochures and data sheets for fire pump controllers. Although not all jockey pump controllers furnished by these manufacturers use this switch, verify the acceptability of this switch as a replacement for other. They are equipped with a mechanical pressure switch and a handoffauto selector switch to control the operation. It is designed to keep the pressure in the system elevated to a specific level when the system is not in use, so that the fire pump doesnt have to run all the time and the system.
They are used for pressure maintenance in fire pump installations to prevent unnecessary operation of the main fire pump. Jockey pumps can be a great way to increase pump station lifecycle. Fire pump room design, details and requirements pdf notes. The test pressure is to be upto 2 times the maximum working pressure of the pump, but in no case less than 250 psi 1724 kpa to ensure no rupture or leakage through the castings at the test pressure. The jockey pump is not as mundane as many engineers, contractors, and installers would have you believe. Download fire pump room design, details and requirements pdf notes. The device is used in residential and office buildings, hospitals, hotels, administrative and industrial buildings. Jockey pumps are small, motor driven pumps used in conjunction with main fire pumps to compensate for minor leaks in the fire protection system and automatically maintain standby pressure. The vertical design requires 30% less space than a. Could anyone share the fire service pump and fire service jockey pump to me.
Each pump is tested hydrostatically for not less than 5 minutes. Hence a jockey pump is an important part of the fire pumps control system. The pump shall be hydrostatically tested at a pressure of not less than one and onehalf times the. Nov 12, 20 a jockey pump will alleviate the wear on the large pumps. We have a fire pump with controller and ats as an integrated unit. There is brochures and data sheets for emerson firetrol fta550f xg jockey pump controller available here for reading and downloading. Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. Feb 17, 2015 fire fighting pump room with fire pump, jockey pump and diesel pump installation details in hindi duration. Pompa pemadam kebakaranjockey fire pump versa pump. Click the quote form button to enter your application details, product specifications and other.
Fire pump package are required to comply with local civil defense authority regulations and international codes of practice e. Pentair fairbanks nijhuis pvm series jockey pumps fire. A jockey pump is sized for a flow less than the flow to one sprinkler in order to ensure a system pressure drop. To order parts you need to know the size of your series 8100 fire pump, for example 8x8x17f. The jockey pump, an important part of a fire pump system. Jockey pumps are typically small multistage centrifugal pumps, and do not have to. Anything over 20 gpm is getting excessive and approaches the flow capacity of some heads. A fire pump is a part of a fire sprinkler systems water supply and powered by electric, diesel or. Fire pump controller and product manuals tornatech. Download pdf versions of any of our literature for free via the link on their page or add to your cart and well mail you laminated versions. Mp15 jockey pump controller service entrance rated.
Starting inrush current is approximately 600% of rated full load amperes. All details and components of fire pump room according to nfpa 20. The jockey pump, an important part of a fire protection system print email august 1, 2009 rev. The other is a low flow, high head jockey pump which keeps the system pressurized during normal nonfire conditions. Aug 29, 2016 the purpose of the jockey pump is to keep the water pressure in the pipes within a specific range when theres not a fire, so that the sprinklers wont go off randomly. A jockey pump will alleviate the wear on the large pumps.
A jockey pump is a small pump connected to a fire sprinkler system in order to maintain a certain pressure in the sprinkler system, and sized to ensure that if a. Usually, a good practice in industry for new underground systems or systems under the maximum allowable underground leakage and nfpa 20 handbook recommendation, 20 edition is that jockey pump will supply 1% of the main pump rated capacity gallons and add 10 psi to the pressure rating of the fire pump. Jockey pump controllers fire pump controllers electrical. Aurora fire pumps 932 page 403 vertical jockey pumps date. Fire pump testing tbp47 1011 weekly operational tests the your business insurance specialists state auto group risk control services this bulletin covers the basic procedure for weekly performance testing of both electric motor and diesel. The armstrong 4700 multistage pumps are designed for reliability and low maintenance cost. Ask for fire service pump and fire service jockey pump. Jockey pumps are small capacity pump which overrides main fire water pump electric motor and diesel. Fire pump sizing the estimated performance of the fire pump between 100% and 150% of rated flow can be calculated using the following formula. Xbdgdl jockey pump set tank and pump packages, jockey pump set, jockey pump, fire jockey pump, fire pump manufacturers, pump jockey. Identify the appropriate sections of nfpa 20 that apply to sizing and layout of fire pumps. Jul 12, 2018 download fire pump room design, details and requirements pdf notes.
Fpt stores all of your fire pump information, calculates flowrates, and graphs pump test curves. From time to time, though, small water leaks, unwanted pressure drops, or even. This is the auxiliary pump or jockey pump that is connected to the booster or fire pump for a sprinkler or fire standpipe system. The jockey lite jockey pump controllers operate acrosstheline, where full voltage is applied to the motor for starting by the use of a single motor starter. This reduces wear on the main pump and controller caused by unnecessary, frequent operation. The jockey pump senses this, and then fills them back up to normal pressure. A jockey pump, also known as a pressuremaintenance pump, is a small apparatus that works together with a fire pump as part of a fireprotection sprinkler system. Jun 05, 2017 if youre referring to sizing the flow rate of a jockey pump as it relates to a normal leakage rate, generally we size the jockey pump flow rate to be 1% of the fire pump s rated gpm 1 gpm per 100 gpm of fire pump. The controller includes an electronic circuit board having a microprocessor mounted thereon, and a solid state pressure sensing device for monitoring a current level of the pressure. Fire pump sets comprise a combination of electric motor driven pump, diesel engine driven and electric motor driven jockey pumps that supply for fire suppression systems. One is the main fire pump which delivers large volumes of water to the fire standpipe system in case of fire.
May 18, 2008 a jockey pump is an important component of a fire pump system. We are looking to feed the jockey pump from load side of the ats but nec section 695. Fire pumps are required to comply with local civil defense authority regulations and international codes of practice e. Download ac fire pump series 8100 horizontal split case parts guide free pdf. Use fire pump tester software to collect fire pump test results professionally, comprehensively, and easily. Jockey pumps in pump station design romtec utilities.
They are equipped with a microprocessor based, color touchscreen which allows the user to monitor and program all functions and values. There shall be no pressure snubber or restrictive orifice employed within. The pump shall be hydrostatically tested and run tested prior to shipment. A jockey pump, also know as a pressure maintenance pump, maintains the pressure in the fire sprinkler system to.
Provisions were also added to address the use of fire pump drivers using variable. Xbdgdl jockey pump set tank and pump packages, jockey pump. There are specific installations that are manual rather than automatic. If you have any questions feel free to contact us through questionsanswers page. The pump manufacturer, armstrong pumps, recommends, as a rule of thumb, to size the jockey for about 1 % of the rated flow of the main fire water pump. Fp jockey fire foam pumps and packages fire lion global. Run fire pumps weekly and record results in the appropriate column. A jockey pump is an important component of a fire pump system. Small horsepower pumps are much less costly to maintain or replace, so using jockey pumps for the bulk of the system operating time is a good design practice. Order reprints no comments what is a jockey pump and why does it carry that title. The jockey pump jp or pressure maintenance pumps pmp as. Except for no test header requirement, a jockey pump has the same basic components as the main fire pump. Jockey pump is set such that it starts at low pressure in header and stop at high pressure to maintain the desire pressure in the network.